Key Beeps

Acc. Modules-Bus Devices (Default=on)

This setting determines whether or not selected
touchpads sound beeps when their buttons are
pressed. This feature is usually turned off if a
touchpad is located in or near bedrooms to avoid
disturbing persons sleeping.

To turn Key Beeps on or off:

1. With the display showing the desired

touchpad, press # + B + # + B. The display
shows

KEY BEEPS OFF/ON

(current setting).

2. Press 1 (off) or 2 (on) to select the desired

setting. The display flashes the entered
selection. Press # and the display shows the
new setting.

Output 1, 2, 3, 4 (081000-output 1) (081010-
output 2) (081020-output 3) (081030-output 4)

Acc. Modules-SnapCards (Defaults: Output
1=01400, Output 2=00410, Output 3=00903,
Output 4=01003)

This setting lets you assign the 5-digit
configuration number for each SnapCard relay
output that determines which system event
activates the output and the duration or time the
output is activated.

The first three digits represent the trigger number
of an event such as an alarm, open sensor, or
arming the system.

The last two digits represent how the output
responds such as momentary, sustained (or
latched), or for a preset time.

Tables A6-A10 in “Appendix A” identify system
event trigger and response numbers.

To assign configuration numbers to
SnapCard Relay outputs:

1. With the display showing

SNAPCARDS

, press

#. The display shows

OUTPUT

PROGRAMMING

.

2. Press # again and the display shows

OUTPUT 1

.

3. Press A or B to select the desired output (1-

4), then press #. The display shows

OUTPUT

n

(current setting).

4. Enter the desired 5-digit configuration

number for this output. The display flashes
the entered number. Press # and the display
shows the new setting.

Onboard Options Menu

The ONBOARD OPTIONS menu lets you set up the following built-in options:

INPUTS—this menu lets you set panel zone input 6 for 2-wire smoke operation
and turn the smoke verification feature off/on.

OUTPUTS—this menu lets you assign the two built-in panel outputs to partitions
and set their configuration numbers.

The following describes how to program the settings that appear under
ONBOARD OPTIONS—INPUTS.