Concord Express Installation Instructions

High Level Rpts (0101-cs phone 1, 0111-cs
phone 2)

Phones-CS Phone 1-2 (Default: CS
Phone 1=on, CS Phone 2=off)

When this setting is on, the panel reports to the
central station events that involve a high-level
security risk, including the following conditions:

Fire, Police, Auxiliary, Duress, and Freeze
alarms

No Activity

Receiver Failure (or jam)

System Tamper (40 incorrect keystrokes or
touchpad supervisory),

Entering or exiting Sensor Test mode

Note

: For UL 1635 listed installations, this feature

must be set to on for the programmed phone
number.

To turn High-Level Reports off or on:

1. With the display showing

HIGH LEVEL

RPTS OFF/ON

(current setting), press 1

(off) or 2 (on). The display flashes the
entered setting.

2. Press # and the display shows the new

setting.

Low Level Rpts (0102-cs phone 1, 0112-cs
phone 2)

Phones-CS Phone 1-2 (Default: CS
Phone 1=on, CS Phone 2=off)

When this setting is on, the panel reports non-alarm
conditions to the central station, including the
following conditions:

Force Armed

Hardwire Zone Trouble (open or short)

Supervisory (wireless devices)

Low Battery (wireless devices)

Other non-alarm related conditions

Note

: For UL 1635 listed installations, this feature

must be set to on for the programmed phone
number.

To turn Low-Level Reports off or on:

1. With the display showing

LOW LEVEL

RPTS OFF/ON

(current setting), press 1

(off) or 2 (on). The display flashes the
entered setting.

2. Press # and the display shows the new

setting.

Open/Close Rpts (0103-cs phone 1,
0113-cs phone 2)

Phones-CS Phone 1-2 (Default=off)

When this setting is on, the panel sends a
report when the system is armed (closed)
or disarmed (opened).

Note

: To use this feature, the Opening

Reports and Closing Reports settings under
the REPORTING menu must be turned on.

To turn Opening/Closing Reports off or on:

1. With the display showing

OPEN/CLOSE RPTS

OFF/ON

(current setting), press 1 (off) or 2 (on).

The display flashes the entered setting.

2. Press # and the display shows the new setting.

Advertising