Chapter 2

42

Concord Express Installation Instructions

Phone Test (02000)

Phones Options-Global (Default=on)

This setting determines if the user can test
the communication from the panel to the
central station (or a pager). When this feature
is on, the user can test communications at
any time by entering 8 + CODE + 2.

Note

: For UL 1635 listed installations, this

feature must be set to on.

To turn the Phone Test setting off or on:

1. With the display showing

PHONE TEST OFF/ON

(current setting), press 1 (off) or 2 (on). The
display flashes the entered setting.

2. Press # and the display shows the new
setting.

Auto Phone Test (02001)

Phones Options-Global (Default=off)

This setting determines if the panel sends a
phone test automatically to the central station
(or a pager) on a predetermined schedule.
(Refer to the “Phone Test Freq.” and “Next
Phone Test” settings found under TIMERS—
GLOBAL).

Note

: For UL 1635 listed installations, this

feature must be set to on.

To turn Automatic Phone Test off or on:

1. With the display showing

AUTO PHONE TEST

OFF/ON

(current setting), press 1 (off) or 2

(on). The display flashes the entered setting.

2. Press # and the display shows the new

setting.

Auto Test Reset (02002)

Phones Options-Global
(Default=on)

This setting determines whether or not the Auto Phone Test
interval is reset after any successful report to the central
monitoring station. Refer to the “Phone Test Freq.” and
“Next Phone Test” settings found under TIMERS—
GLOBAL.

When this feature is on, the panel considers any successful
report to the central station to be a successful phone test.
Thus, any successful panel report to the central monitoring
station resets the Next Phone Test setting to the Phone
Test Freq. value. The panel only conducts an Auto Phone
Test if no other reports are made during the Phone Test
Freq. time period.

When this feature is off, an Auto Phone Test is always
conducted according to the Phone Test Freq. setting, even
if the panel makes other reports to the central monitoring
station during that time period.

Note

: Phone Test Freq must be set to 2 or higher for this

feature to work.

To turn Auto Test Reset off or
on:

1. With the display showing

AUTO

TEST RESET OFF/ON

(current

setting)

, press

1 (off) or 2 (on).

The display flashes the entered
setting.

2. Press # and the display shows

the new setting.