Chapter 2

Concord Express Installation Instructions

55

Force Armed (0515)

Reporting-Partition 1 (Default=off)

This setting determines whether or not the panel
reports to the central monitoring station when a
user force arms the system.

Force Armed occurs if the user presses bypass
when arming the system with open
sensors/zones protesting.

Note

: Auto Force Armed always reports to the

central monitoring station. Auto Force Armed
occurs if the user does not press bypass when
arming the system with open sensors/zones
protesting and the siren time expires.
For UL Listed systems, Force Armed must be
turned off.

To turn Force Armed off or on:

1. With the display showing FORCE ARMED

OFF/ON (current setting), press 1 (off) or 2
(on). The display flashes the entered
setting.

2. Press # and the display shows the new

setting.

Alarm Verify (0516)

Reporting-Partition 1 (Default=off)

This setting determines whether the
panel reports to the central monitoring
station after a single sensor/zone trip (off)
or waits for a second trip before reporting
(on). The second trip must be a different
sensor and occur within 4 minutes of the
first trip.

This setting affects sensors/zones
learned into groups 10 through 20. If
Alarm Verify is set to on, group 18
responds the same as group 17. See
“Appendix A, Table A.3: Sensor Group
Characteristics.”

Note

: For UL Listed systems, Alarm

Verify must be turned off.

To turn Alarm Verify off or on:

1. With the display showing ALARM VERIFY

OFF/ON (current setting), press 1 (off) or 2 (on).
The display flashes the entered setting.

2. Press É and the display shows the new setting.

System Tamper (0517)

Reporting-Partition 1
(Default=off)

This setting determines the following:

Whether or not the armed system goes into alarm if
several incorrect access codes (40 consecutive
keystrokes) are entered.

Whether or not the panel reports to the central station if a
bus device stops communicating with the panel.

Whether or not the panel reports to the central station if an
RF sensor (non fire) is tampered with. Tamper on fire
sensors will always be reported to the central station.

Note

: For UL Listed systems, System Tamper must be turned

on.

To change the System Tamper
setting:

1. With the display showing

SYSTEM TAMPER OFF/ON
(current setting), press 1 (off)
or 2 (on). The display flashes
the entered setting.

2. Press # and the display

shows the new setting.