Interlogix Concord Express Installation Manual User Manual

Page 49

Advertising
background image

Chapter 2

Concord Express Installation Instructions

43

Comm Failure (02003)

Phones Options-Global (Default=on)

When this setting is on, the panel activates
trouble beeps to alert users on the premises
that communication to the central station has
failed. Failure notification occurs after the
third unsuccessful reporting attempt to the
central station (or pager).

Note

: For UL 1635 listed installations, this

feature must be set to on.

To turn Communication Failure notification off
or on:

1. With the display showing

COMM FAILURE

OFF/ON

(current setting), press 1 (off) or 2

(on). The display flashes the entered setting.

2. Press # and the display shows the new
setting.

DTMF Dialing (02004)

Phones Options-Global (Default=on)

This setting determines whether the panel
uses DTMF tones (on) or pulse (off) for
dialing programmed phone numbers.

To turn DTMF Dialing off or on:

1. With the display showing

DTMF DIALING

OFF/ON

(current setting), press 1 (off) or 2

(on). The display flashes the entered setting.

2. Press # and the display shows the new
setting.

Dialer Abort (02005)

Phones Options-Global
(Default=on)

This setting determines whether or not users can stop the
first dialing attempt of the panel (within the Dialer Abort
Delay time setting) to report to the central station. When this
feature is on, alarm reports from sensors in groups 00-20,
34, and 35 can be aborted by entering CODE (or 1 +
CODE) within the Dialer Abort Delay time setting (defaulted
to 30 seconds). Cancel and restoral reports from these
sensor groups are also aborted if the related alarm report
was aborted. Other reports that can be aborted include
System Alarm Tamper/Cancel, No Activity Alarm/Cancel,
Touchpad Police and Auxiliary Panic/Cancel, Recent
Closing, and Two Trip Error. Fire alarm reports to the
central station cannot be aborted.

To turn Dialer Abort off or on:

1. With the display showing

DIALER ABORT OFF/ON

(current

setting), press 1 (off) or 2 (on).
The display flashes the entered
setting.

2. Press # and the display shows

the new setting.

Dialer Abort Delay (02006)

Phones Options-Global (Default=30 sec.)

This setting determines how much time (15 to
45 seconds) the user has to enter the disarm
command in order to prevent the panel from
reporting to the central monitoring station.

Note

: For UL Listed systems, the combined

time for the Entry Delay (0310) and Dialer
Abort Delay must not exceed 60 seconds.

To change the Dial Abort Delay:

1. With the display showing

DIAL ABORT DELAY

nn

(current setting), enter the desired time (15

to 45 seconds). The display flashes the
entered setting.

2. Press # and the display shows the new
setting.

Advertising