Setting 

Default Value 

Comments 

Restart On 
Over Range 

OFF 

This setting forces an algorithm reset when a sensor over range occurs i.e., a 
rotational rate on any of the three axes exceeds the maximum range.   The default 

setting is OFF.  Algorithm reset returns the unit to a high gain state, where the 
unit rapidly estimates the gyroscope bias and uses the accelerometer feedback 

 

  

heavily.   This setting is recommended when the source of over‐range is likely to

be sustained and potentially much greater than the rate sensor operating limit. 
Large and sustained angular rate over‐ranges result in unrecoverable errors in 
roll and pitch outputs.  An unrecoverable error is one where the EKF cannot 

stabilize the resulting roll and pitch reading.    If the over‐ranges are expected to 

be of short duration (<1 sec) and a modest percentage over the maximum 

 setting be 

operating range, it is recommended that the restart on over range

turned off.     
Han ng an inertial rate s

dli

ensor over‐range is controlled with the 

rtOnOverRange

resta

 switch.   

tOnOverRange

 

If restar

is off, the system will flag the overRange status flag and

continue to operate through it.   

• If restartOnOverRangeis on, the system will flag a master Fail error during an 

over‐range condition and continue to operate with this flag until a quasi‐

static condition is met to allow for an algorithm restart.   

The quasi‐static condition required is that the absolute value of each low‐pass 

rate sensor falls below 3 deg/sec to begin initialization.  The system will then 
attempt a normal algorithm start.  

Dynamic 
Motion 

ON 

The default setting is ON.   Turning off the dynamic motion setting results in a 
higher gain state that uses the accelerometer feedback heavily.   During periods of 

d off 

time when there is known low dynamic acceleration, this switch can be turne

to allow the attitude estimate to quickly stabilize.   

Turn Switch 
threshold 

10.0 deg/sec 

With respect to centripetal or false gravity forces from turning dynamics (or 
coordinated turn), the unit monitors the yaw‐rate.  If the yaw rate exceeds a given 

turnSwitch threshold, the feedback gains from the accelerometer signals for 
attitude correction are reduced because they are likely corrupted. 

 

AHRS440 Function 

The AHRS440 (Attitude Heading Reference System) unit includes an additional internal 3‐axis magnetometer and 
associated software running on the DSP processor. This enables the computation of dynamic heading, as well as 

dynamic roll and pitch.   AHRS440 data provides dynamic heading, roll, and pitch measurements, in addition to the 
VG440 and IMU440 data.  The dynamic heading measurement is stabilized using the 3‐axis magnetometer as a 

magnetic north reference.  The dynamic roll and pitch measurements are stabilized using the accelerometers as a 

fined 

long‐term gravity reference. The unit can be configured to turn on and off the magnetic reference for user de
periods of time. 
This function utilizes data from calibrated sensors, the gyroscopes, the accelerometers and a magnetometer 
(internal or external). For details of the IMU functions, refer to IMU440 Function on page 23. For details of the VG 

functions, refer to VG440 (Vertical Gyroscope) Function), on page 25.In addition to those features, the AHRS440 
algorithm has two major phases of operation.  