NAV440 User Manual

7430‐0131‐01 Rev. F 

Continuous Packet Type Field 

This is the packet type that is being continually output.  The supported packet depends on the model number.  

Please refer to 

 on page   for a complete list of the available packet types. 

Output Packets (Polled or Continuous)

71

Analog Filter Clocks 1,2,3 

These three fields set hardware low pass filter cutoff frequencies.  Each sensor listed is defined in the default factory 

tended orientation.   

orientation.  Users must consider any additional rotation to their in
 

 

Table 59  Filter Clocks 

Filter Clock 

 

 

Sensor 

analogFilterClock1 

Ux, Uz Accel 

analogFilterClock2 

Uy Accel 

analogFilterClock3 

Ux, Uy, Uz rate 

Orientation Field 

This field defines the rotation from the factory to user axis sets.  This rotation is relative to the default factory 
orientation (connector aft, base plate down).  The default factory axis set is (Ux, Uy, Uz) defined by the connector 

pointing in the –Ux direction and the base plate pointing in the +Uz direction.  The user axis set is (X, Y, Z) as defined 
by this field.  An example of the factory axis set is shown below: 

Figure 21  Orientation Fields 

 

Table 60  Orientation Fields 

Axis 

Bits 

Values 

X Axis Sign 

0 = positive, 1 = negative 

X Axis 

1:2 

0 = Ux, 1 = Uy, 2 = Uz, 3 = N/A 

Y Axis Sign 

0 = positive, 1 = negative 

Y Axis 

4:5 

0 = Uy, 1 = Uz, 2 = Ux, 3 = N/A 