Moog Crossbow NAV440 Series User Manual

Page 29

Advertising
background image

 

 

 

 

 

NAV440 User Manual 

7430‐0131‐01 Rev. F 

Page 29

 
 

Setting 

Default Value 

Comments 

Freely 
Integrate 

OFF 

The Freely Integrate setting allows a user to turn the unit into a free gyroscope.  In 
free gyroscope mode, the roll, pitch and yaw are computed exclusively from 

angular rate with no Kalman filter based corrections of roll, pitch, or yaw.  When 
turned on, there is no coupling of acceleration based signals into the roll and pitch 

tch, and 

or magnetometer based signals to the yaw.  Due to sensor bias., the roll, pi

yaw outputs will drift roughly linearly with time. 
For best performance, the Freely Integrate mode should be used after the 
algorithm has initialized.  This allows the Kalman Filter to estimate the roll and 

pitch rat

the free 

e sensor bias prior to entering the free gyroscope mode.    Upon exiting 

gyroscope mode (OFF), one of two behaviors will occur: 

nds, 

If the unit has been in freely integrate mode for less than sixty seco
the algorithm will resume operation at normal gain settings 

• If the unit has been in freely integrate mode for greater than sixty 

seconds, the algorithm will force a reset and reinitialize with high gains 

automatically.  

 

Use Mags 

ON 

The 

 

for y

Use Mags setting allows users to turn on and off the magnetometer feedback

aw/heading stabilization.   

• The default setting is ON.  When Use Mags is turned ON, the  440 Series unit 

uses the magnetic field sensor readings to stabilize the drift in yaw, and it 

slaves the yaw to the compass reading provided from the magnetic field 
sensor readings.    

• When Use Mags is turned OFF, the heading (yaw) angle measurement of the 

unit will drift and freely integrate.  In effect, this setting converts the 

 be done on 

functionality to VG.  However, unlike a unit in the VG440, this can
a selectable basis and changed in real time during a mission.    

The reason for this setting is to give the user an ability to turn off the 
magnetometer stabilization when severe magnetic distortion may be occurring.  

This setting is desirable when the user system temporarily moves in close 
proximity to a large ferrous object.    When the Use Mags switch is turned from 

FF to ON, the unit will reinitialize the yaw/heading angle with the compass 

eading provided from the magnetic field sensor readings. 

O

r
 