Jt20 operator’s manual – Ditch Witch JT20 User Manual

Page 166

Advertising
background image

JT20 Operator’s Manual

Service - 165

Startup/10 Hour

CMW

®

Check Pipe Auto Lubricator Spray
Nozzle

Check pipe auto lubricator spray nozzle before
startup and every 10 hours of operation. Ensure
that nozzle is free of obstructions and operates
properly. Clean as needed.

To clean:

1.

Rotate handle to the upward, or cleanout, position (A).

2.

Operate pump until obstruction is flushed.

3.

Rotate handle to the downward, or spray, position (B).

4.

Clean nozzle guard. If necessary, pull handle/nozzle insert out of housing to clean with fine wire or
solvent.

Check Pipe Auto Lubricator TJC Level

Check pipe auto lubricator TJC level before
startup and every 10 hours of operation. Change
pail as needed. See “Change Auto Lubricator
TJC Pail” on page 179 for procedure.

NOTICE: Ditch Witch

®

tool joint compound is

specially formulated to work with Ditch Witch
pipe lubrication system. Use of other tool joint
compounds will clog system. See
“Recommended Lubricants/Service Key” on
page 159 for more information.

NOTICE: Ditch Witch

®

tool joint compound is

specially formulated to work with Ditch Witch
pipe lubrication system. Use of other tool joint
compounds will clog system. See
“Recommended Lubricants/Service Key” on
page 159 for more information.

j38om015w.eps

j38om016w.eps

Advertising