Troubleshoot strike system, Jt30 /jt30 all terrain operator’s manual – Ditch Witch JT30AT User Manual

Page 134

Advertising
background image

JT30 /JT30 All Terrain Operator’s Manual

Systems and Equipment - 134

Electric Strike System

CMW

Troubleshoot Strike System

When strike system detects a problem, a diagnostic code will be displayed. Anytime this happens, go to
the ESID menu and select test function to retest. If a diagnostic code is still displayed and does not appear
in this chart, have control module checked or replaced.

Other problem situations and their possible causes and solutions are listed in the chart below.

Problem

Possible cause

Possible solution

V and A flashing on
Information Center ESID
display

Problems in startup

Go to ESID menu and select test
function. If problem goes away, retest
strike system

No power to strike system
control module

Check drilling unit electrical system

Check that harness from drilling unit
to control module is connected

Check that cable from drilling unit
carries more than 10V

Defective control module

Have control module checked or
replaced

Defective CAN bus connection

Ensure CAN cable from drilling unit to
ESID control module is connected

dc513 Test Wire shows on
Information Center

Test wire not connected

Check that test wire is connected to
ESID control module

Check that test wire is connected to
Information Center

Have ESID control module checked
or replaced

Strobe light on drilling unit
does not work during total
test

Improper connections with
control module

Check connections and wiring
harness

Defective strobe light

1.

Disconnect strobe and connect to
external 12V power source.

2.

If alarm does not work, replace it.

Defective control module

Have control module checked or
replaced

Alarm on drilling unit does
not work during total test

Improper connections with
control module

Check connections and wiring
harness

Defective alarm

1.

Disconnect alarm and connect to
external 12V power source.

2.

If strobe does not work, replace it.

Defective control module

Have control module checked or
replaced

Advertising