50 hour, Drilling unit, Jt30 /jt30 all terrain operator’s manual – Ditch Witch JT30AT User Manual

Page 212

Advertising
background image

JT30 /JT30 All Terrain Operator’s

Manual

Service - 212

50 Hour

CMW

50 Hour

Drilling Unit

Change Fluid Pump Oil (Initial Service)

Change fluid pump oil at first 50 hours and every
2000 hours thereafter.

To change:

1.

Drain at plug (3). Ensure that magnetic drain
plug is cleaned of debris before reinstalling.

2.

Add NDO at fill plug (2). Maintain fluid level at
fill plug (2). Inspect oil level at sight glass (1).

Location

Task

Notes

DRILLING
UNIT

Change fluid pump oil

Initial service, NDO

Check radiator

Change hydraulic filters

Initial service

Check ground drive gearbox oil level

2 gearboxes, MPL

Check rotation gearbox oil level

MPL

Inspect thrust rollers

Check hex stub

Drain water from hydraulic tank

Check thrust drive gearbox oil level

Check anchor drive gearbox oil level

Advertising