Jt30 /jt30 all terrain operator’s manual – Ditch Witch JT30AT User Manual

Page 135

Advertising
background image

Systems and Equipment - 135

JT30 /JT30 All Terrain Operator’s Manual

Electric Strike System

CMW

Strobe light and alarm on
drilling unit do not work
during total test

Improper connections with
control module

Check connections and wiring
harness

Defective control module

Have control module checked or
replaced

dc518 POST AC I code
displays and A is flashing
on Information Center ESID
display

Improper connections with
control module

Check cable connections on control
module and current transformer

Defective current transformer

1.

Disconnect current transformer.

2.

Check for 20-40 ohms from pin 1
to pin 4, 20-40 ohms from pin 1 to
pin 2, and less than 1 ohm from
pin 2 to pin 4.

Defective current transformer
cable

1.

Disconnect cable from
transformer and control module.

2.

Check continuity of cable.

3.

If continuity is zero or cable is
damaged, replace.

Defective control module

Have control module checked or
replaced

dc517 POST AC V code
displays and V is flashing
on Information Center ESID
display

Improper connection of voltage
limiter to ground stake

Check voltage limiter connection to
ground stake and verify that ground
stake is driven into the ground

Defective voltage limiter

Have voltage limiter checked or
replaced

Defective control module

Have control module checked or
replaced

Problem

Possible cause

Possible solution