Jt30 /jt30 all terrain operator’s manual – Ditch Witch JT30AT User Manual

Page 208

Advertising
background image

JT30 /JT30 All Terrain Operator’s

Manual

Service - 208

Startup/10 Hour

CMW

Check Hydraulic Fluid Level

Check hydraulic fluid level before startup and every
10 hours of operation. Maintain fluid level at
halfway point on sight glass (2), when engine is off
and fluid is cool. Add THF at hydraulic fluid fill (1).

Check Fluid Pump Oil Level

Check fluid pump oil level at sight glass (1) before
startup and every 10 hours of operation. Add NDO
at fill (2) as needed.

Check Fluid Pump Piston Seals

Check piston seals for signs of excessive leakage
before startup and every 10 hours of operation.
Replace if leakage becomes excessive. See your
Ditch Witch dealer for replacement parts.

IMPORTANT: If hydraulic system must be
opened for repair, install new filter (p/n 153-791)
for first 50 hours of operation. If this filter
becomes plugged in fewer than 20 hours,
replace with new filter. After 50 hours of normal
operation, replace with new filter (p/n 153-792).

Advertising
This manual is related to the following products: