Machine diagnostic system overview, Code severity levels, Machine diagnostic codes – Ditch Witch JT30AT User Manual

Page 177: Jt30 /jt30 all terrain operator’s manual

Advertising
background image

Systems and Equipment - 177

JT30 /JT30 All Terrain Operator’s Manual

Diagnostic Codes

CMW

Machine Diagnostic System Overview

Use the Information Center to view condition of the machine automation diagnostic system. Under normal
operating conditions, any diagnostic code that is recorded will be shown on the bottom line of the
Information Center. Non-essential codes will remain for 10 seconds and then go away. Essential codes will
remain until the operator clears them from the display. If diagnostic codes are detected, the diagnostic light
will either flash on and off for 10 seconds to indicate a non-essential code or remain on for 3 seconds and
off for half a second to indicate an essential code.

Code Severity Levels

Diagnostic codes are given one of two levels of severity.

A non-essential code affects non-essential functions of the unit. If the system detects a non-essential
problem, a diagnostic code will be recorded and the diagnostic light will flash for 10 seconds and then
go out. Each time ignition is turned on, full operation will be available until the diagnostic system
detects a problem.

An essential code affects rotation, thrust, drilling fluid, or ground drive. If the system detects an
essential problem, a diagnostic code will be recorded and the diagnostic light will cycle on for three
seconds and off for 1/2 second. Some machine functions may not work until the problem is corrected.
Each time ignition is turned on, full operation will be available until the diagnostic system detects a
problem.

Machine Diagnostic Codes

The following table lists the attributes of each diagnostic code. Information presented includes: code
number, condition causing code to be sent, result, and level of severity.

Code

Display

Condition

Result

Severity

12

START MSG

normal entry into diagnostic
mode

code is not stored

n/a

13

m12VOLT
OUTPUT

no 12V power to main
controller

drill and drive are blocked

essential

14

m5VOLT OUTPUT

no 5V power from main
controller

drill and drive are blocked

essential

15

m6VOLT DRIVER

incorrect voltage on 6V
driver on main controller

drive is blocked

essential

16

p12VOLT OUT

no 12V power to pipe
controller

drill fluid is blocked

essential

17

p5VOLT OUT

no 5V power from pipe
controller

drill fluid is blocked

essential

18

p6VOLT DRIVER

incorrect voltage on 6V
driver on pipe controller

code is stored

essential

19

MISC OUTPUT

unknown output driver
continuity problem

code is stored

non-
essential

Advertising