Systems and Equipment - 180

Diagnostic Codes

CMW

87

HARNESS POSN

ID state does not agree with
harness position and cannot
be resolved

controller runs in EDT only
mode

essential

88

CAN BOOT TO

timeout has occurred while
waiting for CAN system to
boot

controller runs in service
mode

essential

91

CAN PHYS ERR

errors on the CAN Bus
totalling 275 have been
logged

code is stored

non-
essential

92

MAIN BUS OFF

main controller has
shutdown CAN
communications

controller runs in main
service mode

essential

93

PIPE BUS OFF

pipe controller has shutdown
CAN communications

controller runs in pipeloader
service mode

essential

94

MAIN PROTOCOL

main controller has an
incorrect protocol message

code is stored

non-
essential

95

PIPE PROTOCOL

pipe controller has an
incorrect protocol message

code is stored

non-
essential

96

MAIN NG FAIL

main controller has detected
node guard timeout

controller runs in main
service mode

essential

97

PIPE NG FAIL

pipe controller has missed a
node guard from the master

controller runs in pipeloader
service mode

essential

98

MAIN LOG FAIL

pipe controller has had an
internal software failure

controller runs in main
service mode

essential

99

PIPE LOG FAIL

pipe controller has had an
internal software failure

controller runs in pipeloader
service mode

essential

111

TETH NG FAIL

tether controller has missed
a node guard from the main
controller

drive is blocked

essential

112

ESID NG FAIL

ESID controller has missed
a node guard from the main
controller

code is stored

non-
essential

113

ICTR NG FAIL

Information Center has
missed a node guard from
the main controller

code is stored

non-
essential

131

THREAR HSW

no continuity to thrust rear
home switch

add pipe and remove pipe
are blocked

non-
essential

132

THFRNT HSW

no continuity to thrust front
home switch

add pipe and remove pipe
are blocked

non-
essential