1000 hour, Drilling unit, Jt30 /jt30 all terrain operator’s manual – Ditch Witch JT30AT User Manual

Page 220

Advertising
background image

JT30 /JT30 All Terrain Operator’s

Manual

Service - 220

1000 Hour

CMW

1000 Hour

Drilling Unit

Change Hydraulic Fluid and Filters

Change hydraulic fluid and filters every 1000
hours.

To change:

1.

Drain hydraulic oil at drain (3).

2.

Change hydraulic filters. See “Change
Hydraulic Filters (Normal Conditions)” on
page 218.

3.

Add (2) THF.

Location

Task

Notes

DRILLING
UNIT

Change hydraulic fluid and filters

THF

Change ground drive gearbox oil

2 gearboxes, MPL

Change rotation gearbox oil

MPL

Change spindle brake oil

THF

Change thrust drive gearbox oil

2 gearboxes, MPL

Change anchor driver gearbox oil

2 gearboxes, MPL

IMPORTANT: Change oil and filter every 500
hours if jobsite temperature exceeds 100°F
(38°C) more than 50% of the time.

Advertising