Selftestresults – Echelon OpenLNS User Manual

Page 474

Advertising
background image

OpenLNS Programmer's Reference

437

in the

LonMarkAlarm

property of the

LonMarkObject

will be cleared until the

next alarm condition occurs.
11

lcaLonMarkObjectRequestAlarmNotify

Enabled
Enables alarm notification for the

LonMarkObject

.

12

lcaLonMarkObjectRequestAlarmNotify

Disabled
Disables alarm notification for the

LonMarkObject

.

13 lcaLonMarkObjectRequestManual

Control
Places the

LonMarkObject

under manual

control.
14 lcaLonMarkObjectRequestRemote

Control
Places the

LonMarkObject

under remote

control.
15 lcaLonMarkObjectRequestProgram
Reserved.
16

lcaLonMarkObjectRequestClearReset
Cancels the reset of the

LonMarkObject

.

You can initiate a reset by writing the

lcaLonMarkObjectRequestReset (17)

property to the Request property.
17 lcaLonMarkObjectRequestReset
Resets the

LonMarkObject

. You can check

whether or not the reset is complete by

reading the object’s

ResetComplete

property.

Data Type

Long.

Read/Write

Write

-only.

Added to API

Prior to LNS Release 3.0.

SelfTestResults

Summary

Returns an

ObjectStatus

object that reports the results of a

self-test request of this object

.

Getting the value of this object automatically runs the

object’s self-test. However, if the self-test takes more than 20

seconds, an exception will be raised.