Fault description

Possible cause

Required measures

Ventilation (continued)
No fresh air and/or no exhaust air

flow.
LED “AIR” (3) is lit.
Indication “RESET ALARM” in

Display 2.
Acoustical signal (can be reset on

the controller)

Intake opening blocked

(soiled filter).

Change or clean filter. Check ex-

haust air system (customer side).

Intake air channel blocked.

Check exhaust air system (customer

side).

Exhaust air channel blocked.

No pressure differential signal at

the pipe ends

The measuring pipe in the

exhaust passage blocked.

Contact BINDER service.

Pressure differential not sufficient

to switch the pressure switch

Rupture of pressure differential

measuring hose.

Contact BINDER service.

Controller
Program duration longer than

programmed.

Inappropriate tolerances have

been programmed.

For rapid transition phases, do NOT

program tolerance limits in order to

permit maximum heating speed.

Program stops one section too

early.

Program line is incomplete.

When programming, define the end

value of the desired cycle by adding

an additional section with a section

time of at least one minute (with

setting set-point ramp).

Programs have been deleted.

Change from 2 programs to 1

program or vice-versa

When changing, ensure that the

programs are no longer needed.

The controller returns to Normal

Display from any level.

No button was pressed for

more than 120 sec.

Repeat entries, enter the values

rapidly.

Message RANGE ERROR CH1

in Normal Display in Display 2

Sensor rupture between sen-

sor and controller

Contact BINDER service.

Ramp temperature transitions are

only realized as steps.

Set-point programming type

set to “Step” in the User level

(chap. 10).

Set the set-point programming type

ti setting “Ramp” in the User level

(chap. 10).

Only qualified service personnel authorized by BINDER must perform repair.

Repaired units must comply with the BINDER quality standards.

Every fire and explosion in relation to a lacquer dryer must be reported to the employer’s liabil-

ity insurance association (for Germany).