Casella CEL CEL-440 User Manual

Page 14

Advertising
background image

Time:

F (fast), S (slow),

I

(impulse),

Q:

3, 4, 5, 6 energy conversion factor.

Broadband models can measure all of the following parameters
simul-taneously.

L

AF

Sound level, with current weightings (A and F
are shown),

L

AFmx

Maximum level, with current weightings,

L

AFmn

Minimum level, with current weightings,

L

Aeq

Equivalent continuous level, with current
frequency weighting,

L

AIeq

Equivalent continuous level, with impulse
weighting,

L

Zpk

Linear peak,

L

AE

Sound exposure level (sometimes known as SEL),

L

EP,v

Noise dose normalised to a user selected
(variable) period of hours and minutes,
When the period is set to 8 hours, this will be
shown as L

EP,d

.

L

Tm3

Cumulative average of fast weighted maximum
values taken over 3 s periods (Taktmaximal 3),

L

Tm5

Cumulative average of fast weighted maximum
values taken over 5 s periods (Taktmaximal 5),

L

AFNN.N

Five percentile values using current weightings
with values between 0.0% and 99.9% that can
be set by the user,

TWA

v

Time Weighted Average is the normalised time
averaged sound pressure level with the selected
frequency and time weighting that represents
the total L

Avg

of a person’s workplace noise

exposure averaged over a user selected
(variable) period of hours and minutes.
This unit is specified in the USA: OSHA standard
1910-95 published in 1983. When the period is
set to 8 hours, the unit will be shown as TWA.

L

Avg

Average level over the measurement period.

Narrow band models can measure and scan the following parameters