3 hpi domain events, Table 4-8, Domain connection sensor reading – Artesyn System Management Interface Based on HPI-B (Centellis CO 31kX-4100-2000-4410) (June 2014) User Manual
Page 49: Table 4-9, Domain connection sensor events, Hpi domain events, Using hpi-b
Using HPI-B
System Management Interface Based on HPI-B (Centellis CO31kX/4100/2000/4410) User’s Guide
49
4.3.3.3
HPI Domain Events
Depending on the connection status, the Domain Connection sensor can throw events. The
following table provides details.
Category
SAHPI_EC_AVAILABILITY
EventCtrl
SAHPI_SEC_PER_EVENT
Events
SAHPI_ES_ON_LINE | SAHPI_ES_OFF_LINE
Ignore
SAHPI_FALSE
DataFormat - ReadingFormats
SAHPI_SRF_EVENT_STATE
DataFormat - IsNumeric
SAHPI_FALSE
DataFormat - IsThreshold
SAHPI_FALSE
Oem
0
Table 4-8 Domain Connection Sensor Reading
SaHpiSensorReadingT
Value
ValuesPresent
SAHPI_SRF_EVENT_STATE
EventStatus - SensorStatus
SAHPI_SENSTAT_EVENTS_ENABLED |
SAHPI_SENSTAT_SCAN_ENABLED
AssertEvents
SAHPI_ES_ON_LINE
for a connection to a shelf
SAHPI_ES_OFF_LINE
when there is no
connection to a shelf
Table 4-7 Domain Connection Sensor (continued)
SaHpiSensorRecT
Value
Table 4-9 Domain Connection Sensor Events
Event
Description
SAHPI_ES_OFF_LINE
No connection
SAHPI_ES_ON_LINE
Connection is established. Only now is the
domain of the shelf accessible.