Example applications – Artesyn System Management Interface Based on HPI-B (Centellis CO 31kX-4100-2000-4410) (June 2014) User Manual

Page 97

Advertising
background image

Example Applications

System Management Interface Based on HPI-B (Centellis CO31kX/4100/2000/4410) User’s Guide

97

dual-flash-bank boards.

Options:

-d DOMAIN_ID use domain with id DOMAIN_ID

-r RESOURCE_ID use resource with id RESOURCE_ID

-b BANK_NUM set boot bank number to BANK_NUM [0/1]

-V print version information and exit

-h display this help and exit

#------------------------------#

# hpibootoptions

#------------------------------#

Usage: hpibootoptions [OPTION]... [PARAM# PARAMS]

HPI example application to manage the system boot options defined in IPMI

v2.0 .

Options:

-d DOMAIN_ID use domain with id DOMAIN_ID

-r RESOURCE_ID use resource with id RESOURCE_ID

-c turn on console redirection

(Not applicable on some boards)

-o turn off console redirection

(Not applicable on some boards)

-x perform FRU cold-reset

-V print version information and exit

-h display this help and exit

Examples:

Set the system boot option 1 (service partition) to value 2 for resource 4 on

domain 0:

hpibootoptions -d 0 -r 4 1 2

Turn on console redirection and perform a cold-reset for resource 34 on

domain

0:

hpibootoptions -d 0 -r 34 -c -x

#------------------------------#

# hpichassisstatus

#------------------------------#

Usage: hpichassisstatus [OPTION]...

HPI example application to display the control state of the chassis status

control.

Advertising