Table 4-43, Virtual cooling resource - fan control, Table 4-44 – Artesyn System Management Interface Based on HPI-B (Centellis CO 31kX-4100-2000-4410) (June 2014) User Manual

Page 82: Virtual cooling resource - fan control states, Using hpi-b

Advertising
background image

Using HPI-B

System Management Interface Based on HPI-B (Centellis CO31kX/4100/2000/4410) User’s Guide

82

Entity

Cooling resource entity

IsFru

Unused

RdrTypeUnion

CtrlRec
See

Table 4-43 on page 82

IdString

Fan Control

Table 4-43 Virtual Cooling Resource - Fan Control

SaHpiCtrlRecT

Value

Num

MOTHPI_CTRL_NUM_COOLING

OutputType

SAHPI_CTRL_GENERIC

Type

SAHPI_CTRL_TYPE_DISCRETE

TypeUnion.Analog.Min

Minimum blower speed level

TypeUnion.Analog.Max

Maximum blower speed level

TypeUnion.Analog.Default

Default blower speed level

DefaultMode.Mode

SAHPI_MODE_AUTO

DefaultMode.ReadOnly

SAHPI_FALSE

WriteOnly

SAHPI_FALSE

Table 4-44 Virtual Cooling Resource - Fan Control States

SaHpiCtrlStateT

Value

Type

SAHPI_CTRL_TYPE_ANALOG

StateUnion.Analog

Current fan level calculated by cooling algorithm.
This can always be read, independent of the cooling
mode (internal/external).

Table 4-42 Virtual Cooling Resource - Fan Control RDR (continued)

SaHpiRdrT

Value