Using HPI-B

System Management Interface Based on HPI-B (Centellis CO31kX/4100/2000/4410) User’s Guide

83

As mentioned above, each domain furthermore contains HPI resources which represent fans in
a shelf. There is one fan resource for each fan. The fan resources allow you to control the fan
speeds of individual fans. The entity paths and ID strings of these resources are given in the
following table. The control mode of an individual fan cannot be changed, it will always be the
same mode as the mode of the virtual cooling control.

The RDR definitions are given in the following two tables.

Table 4-45 Fan Resource - Entity Path and ID String

Property

Entity Path

Entity Path

{ADVANCEDTCA_CHASSIS, <SGA>}{FAN_TRAY_SLOT, <fan
num.>}{COOLING_UNIT,0}

ID String

FAN MODULE

Table 4-46 Fan Resource - RDR

SaHpiRdrT

Value

RecordId

Assigned by HPI

RdrType

SAHPI_CTRL_RDR

Entity

Fan resource entity

IsFru

Unused

RdrTypeUnion

CtrlRec
See

Table "Fan Resource - Control" on page 83

IdString

Fan 0 Control

Table 4-47 Fan Resource - Control

SaHPICtrlRecT

Value

Num

MOTHPI_CTRL_NUM_FAN

OutputType

SAHPI_CTRL_FAN_SPEED

Type

SAHPI_CTRL_TYPE_ANALOG

TypeUnion.Analog.Min

Minimum blower speed level

TypeUnion.Analog.Max

Maximum blower speed level