POST Type Control

This HPI control allows you to set/get the Power-On Self Test (POST) type of the blade. Two
POST types are configurable: long POST and short POST. Refer to the respective hardware user
manual of the blade for details about both POST types. The definition of the respective HPI
controls is given in the following tables.

Table 4-13 POST Type HPI Control RDR

SaHpiRdrT

Value

Notes

RecordId

Assigned by HPI implementation

Unique
identifier for
the RDR

RdrType

SAHPI_CTRL_RDR

RdrTypeUnion.CtrlRec.Num

MOTHPI_CTRL_NUM_POSTTYPE

RdrTypeUnion.CtrlRec.OutputType

SAHPI_CTRL_OEM

Indicates
that this
control does
not correlate
to any of the
given control
output
types, and
describes a
generic
control
output.

RdrTypeUnion.CtrlRec.Type

SAHPI_CTRL_TYPE_DISCRETE

RdrTypeUnion.CtrlRec.TyoeUnion.D

iscrete.Default

0x0

RdrTypeUnion.CtrlRec.Oem

Assigned by HPI implementation

IdString

MOTHPI_CTRL_NAME_POSTTYPE

Table 4-14 POST Type HPI Control Sate Values

SaGPISateT

Value

Notes

Type

SAHPI_CTRL_TYPE_DISCRETE