5 hpi logging support, Table 4-16, Log rdr – Artesyn System Management Interface Based on HPI-B (Centellis CO 31kX-4100-2000-4410) (June 2014) User Manual
Page 57: Using hpi-b
Using HPI-B
System Management Interface Based on HPI-B (Centellis CO31kX/4100/2000/4410) User’s Guide
57
4.4.5
HPI Logging Support
The actions taken by the HPI daemon are written to a log file. The path and name of the log file
is defined in the configuration file bbs-hpib.conf.
To control what kind of information is written to the log file, the log control can be used.
Refer to the header file MotorolaHpi.h for used defines.
Shelf alarm LEDs
Centellis 2000
The shelf alarm LEDs are controlled through the LED controls which
are attached to the HPI-B shelf resource.
Centellis CO 31K/4100
Not applicable. There are no shelf alarm LEDs in these systems.
Centellis 1410
The shelf alarm LEDs are located on the Alarm Display Panel at the
front of the shelf and are controlled by the Minor Alarm, Major Alarm,
and Critical Alarm controls associated with the shelf manager
resources.
Table 4-15 Shelf-Specific Mapping of HPI Controls (continued)
Feature
Note
Table 4-16 Log RDR
SaHpiRdrT
Value
RecordId
Assigned by HPI
RdrType
SAHPI_CTRL_RDR
Entity
The same entity as logical shelf resource
RdrTypeUnion
Defined in next table
IdString
MOTHPI_CTRL_NAME_LOG
found in