Using HPI-B

System Management Interface Based on HPI-B (Centellis CO31kX/4100/2000/4410) User’s Guide

57

4.4.5

HPI Logging Support

The actions taken by the HPI daemon are written to a log file. The path and name of the log file
is defined in the configuration file bbs-hpib.conf.

To control what kind of information is written to the log file, the log control can be used.

Refer to the header file MotorolaHpi.h for used defines.

Shelf alarm LEDs

Centellis 2000
The shelf alarm LEDs are controlled through the LED controls which
are attached to the HPI-B shelf resource.
Centellis CO 31K/4100
Not applicable. There are no shelf alarm LEDs in these systems.
Centellis 1410
The shelf alarm LEDs are located on the Alarm Display Panel at the
front of the shelf and are controlled by the Minor Alarm, Major Alarm,
and Critical Alarm controls associated with the shelf manager
resources.

Table 4-15 Shelf-Specific Mapping of HPI Controls (continued)

Feature

Note

Table 4-16 Log RDR

SaHpiRdrT

Value

RecordId

Assigned by HPI

RdrType

SAHPI_CTRL_RDR

Entity

The same entity as logical shelf resource

RdrTypeUnion

Defined in next table

IdString

MOTHPI_CTRL_NAME_LOG

found in

MotorolaHpi.h