Shelf-Specific Mappings

The following table contains some notes on shelf-specific usage/mapping of HPI controls.

StateUnion.Discrete

Bits 7..0

:

0

: Short POST

1

: Long POST

Bits 15..8

: CPU complex number

Bits 31..16

: Reserved

The POST type value
is specified in the
least significant
byte.
The CPU number (or
SET Selector byte) is
normally zero.
However, for blades
that support more
than one CPU
complex, the
processor complex is
identified with this
field.

Table 4-14 POST Type HPI Control Sate Values (continued)

SaGPISateT

Value

Notes

Table 4-15 Shelf-Specific Mapping of HPI Controls

Feature

Note

Shelf geographical address

Centellis CO 31K/4100/4410:
The shelf geographical address is determined by a rotary switch on
the ATCA-A100. HPI-B allows you only to read the shelf geographical
address.
Centellis 2000
Here the shelf geographical address can only be changed via HPI-
B/IPMI. This is the only way to modify it.