Jumper positions wye-(2, Jumper positions (1-(1, Jumper positions wye-∆2 -22 – Basler Electric BE1-87T User Manual

Page 118: Jumper positions ∆1-∆1 -22

Advertising
background image

5-22

BE1-87T Test Procedures

9171300990 Rev V

This verifies the A- and C-phase differential circuits which respond together as provided

earlier

in the

Verification Tests: 5 Amp CT or Verification Tests: 1 Amp CT

in this section. The B-

phase differential circuit sees no current and does not respond.

Step 3. Connect Input 1 current to terminals B and C.

Connect Input 2 current to terminals B and N.

This verifies the B- and C-phase differential circuits which respond together as provided

earlier

in the

Verification Tests: 5 Amp CT or Verification Tests: 1 Amp CT

in this section. The A-

phase differential circuit sees no current and does not respond.

Jumper Positions WYE-2

Step 1. Connect Input 1 current to terminals A and B.

Connect Input 2 current to terminals N and B.

This verifies the A- and B-phase differential circuits which respond together as provided

earlier

in the

Verification Tests: 5 Amp CT or Verification Tests: 1 Amp CT

in this section. The C-

phase differential circuit sees no current and does not respond.

Step 2. Connect Input 1 current to terminals A and C.

Connect Input 2 current to terminals A and N.

This verifies the A- and C-phase differential circuits which respond together, as provided

earlier

in the

Verification Tests: 5 Amp CT or Verification Tests: 1 Amp CT

in this section. The B-

phase differential circuit sees no current and does not respond.

Step 3. Connect Input 1 current to terminals B and C.

Connect Input 2 current to terminals N and C.

This verifies the B- and C-phase differential circuits which respond together as provided

earlier

in the

Verification Tests: 5 Amp CT or Verification Tests: 1 Amp CT

in this section. The A-

phase differential circuit sees no current and does not respond.

Jumper Positions 1-1

Step 1. Connect Input 1 current to terminals A and N.

Connect Input 2 current to terminals A and N.

This verifies the A- and B-phase differential circuits which respond together. The C-phase

differential circuit sees no current and does not respond.

Step 2. Connect Input 1 current to terminals B and N.

Connect Input 2 current to terminals B and N.

This verifies the B- and C-phase differential circuits which respond together as provided

earlier

in the

Verification Tests: 5 Amp CT or Verification Tests: 1 Amp CT

in this section. The A-

phase differential circuit sees no current and does not respond.

Step 3. Connect Input 1 current to terminals C and N.

Connect Input 2 current to terminals C and N.

Advertising