Power Supply

Refer to Table 1-3.

Table 1-3. Power Supply Ratings

Type

Nominal

Input Voltage

Input Voltage Range

Burden at

Nominal

K (midrange)

48 Vdc

24 to 150 Vdc

9.0 W

J (midrange)

125 Vdc

24 to 150 Vdc

9.0 W

120 Vac

90 to 132 Vac

21.0 VA

L (low range)

24 Vdc

12 to 32 Vdc *

9.0 W

Y (midrange)

48 Vdc

24 to 150 Vdc

8.5 W

125 Vdc

24 to 150 Vdc

9.0 W

Z (high range)

250 Vdc

68 to 280 Vdc

9.5 W

240 Vac

90 to 270 Vac

28.0 VA

*

Type L power supply initially requires 14 Vdc to begin operating. Once operating, the input voltage may

be reduced to 12 Vdc and operation will continue.

Surge Withstand Capability

Qualified to ANSI/IEEE C37.90.1-1989, Standard Surge

Withstand Capability (SWC) Tests for Protective Relays and

Relay Systems, and IEC 255-5 Impulse Test and Dielectric

Test.

Radio Frequency Interference

(RFI)

Maintains proper operation when tested in accordance with

IEEE C37.90.2-1987, Trial-Use Standard Withstand

Capability of Relay Systems to Radiated Electromagnetic

Interference from Transceivers.

UL Recognition

UL Recognized per Standard 508, UL File No. E97033. Note:

Output contacts are not UL Recognized for voltages greater

than 250 V.

GOST-R Certification

GOST-R certified per the relevant standards of Gosstandart

of Russia.

Patent

Patented in U.S., 1991, U.S. Patent No. 5014153.
Patented in Canada, 1993.

Shock

In standard tests, the relay has withstood 15 g in each of

three mutually perpendicular axes without structural damage

or degradation of performance.

Vibration

In standard tests, the relay has withstood 2 g in each of three

mutually perpendicular axes swept over the range of 10 to

500 Hz for a total of six sweeps, 15 minutes each sweep,

without structural damage or degradation of performance.

Operating Temperature

40°C (–40°F) to 70°C (158°F)

Storage Temperature

65°C (–85°F) to 100°C (212°F)