The Default USB play routings are:

Line Out:

USB 1+2

Monitor Out:

USB 1+2 and 3+4

Phones:

USB

1+2

and

5+6

Digital Out XLR (AES): USB 1+2 and 7+8
Digital Out Coax:

USB 1+2 and 9+10

Digital Out Optical:

USB 1+2 and 11+12

ADAT Out 1-8:

USB 1+2 and 9-16 (when Hilo is in 16-channel mode)


3.4.8.4 Outputs


You may have noticed that, with the exception of the USB play channels, all input sources are muted/off by default.
The output sources are the opposite, all un-muted/on by default. To select an Output to assign input sources to, to mute,
or to control its level, press the Output Selection button to reveal the Select Output menu:

Outputs are labeled clearly for selection.

Unlike with input sources, all three digital outputs are
individually selectable, as are the ADAT Outputs

Please note, if the Optical Out Mode on the Home menu is set
to SPDIF, then the ADAT outputs will not be shown and
cannot be selected. If the Optical Out Mode is set to ADAT,
then the SPDIF OPT option will be grayed out and cannot be
selected. Note - when one wishes to use ADAT I/O, it would
be more typical to select 16-channel mode, so that the ADAT
channels can be independent from the other Hilo outputs.

When the 16-channel USB Mode is engaged, all 16 USB input and
output channels are visible and available.