Super Systems SD Recorder II User Manual

Page 14

Advertising
background image

Super Systems Inc.

Page 14 of 50

SD Recorder II Operations Manual

Pen Settings

Pen Color – Color of the pen on the chart.

Pen Width – Width of the pen line on the

chart.

Pen Active – True or False – when false, the

pen and the pen's scales will not be displayed

on the chart, legend, lists or printed reports.

Pen Backup – These settings discussed

below.

Name – Name displayed for this pen in the

Chart Legend.

TID – The TagID for a Normal pen (with SDIO,

the TagID is (channel * 10000 + slot) . For a

Special pen, this will be an index based on the

number of Special Pens in the chart.

TagExpression – Expression used to define a

function of the Tag or for “Special” pens a

function of more than one Tag.

Scale Title – Title to print with scale – leave

blank for no title (this will save space).

Scale Location – There are 3 options:

• None – scale not displayed

• Left – displayed on the left

• Right – displayed on the right

Min Scale – Minimum Scale value for this pen.

Max Scale – Maximum Scale value for this

pen.

Scale Format – Format string for this scale –

also used to format the pen values displayed in

the ChartLegend.

Scale Type – Normally linear. Exponent and

Log are also available for exponent or log data.

Note. For selected SuperSystems 9000 series instruments, Tag Expression, Min Scale,

Max Scale and Scale Format will default to normally expected values.