[DeviceD-GigabitEthernet1/0/1] smart-link flush enable control-vlan 10 110

[DeviceD-GigabitEthernet1/0/1] quit

# Configure GigabitEthernet 1/0/2 as a trunk port and assign it to VLANs 1 through 200. Disable the
spanning tree feature and enable flush message receiving on it, and configure VLAN 10 and VLAN 110

as the receive control VLANs.

[DeviceD] interface gigabitethernet 1/0/2

[DeviceD-GigabitEthernet1/0/2] port link-type trunk

[DeviceD-GigabitEthernet1/0/2] port trunk permit vlan 1 to 200

[DeviceD-GigabitEthernet1/0/2] undo stp enable

[DeviceD-GigabitEthernet1/0/2] smart-link flush enable control-vlan 10 110

[DeviceD-GigabitEthernet1/0/2] quit

5.

Verify the configuration.

Suppose the optical fiber between Device A and Device B fails. You can use the display smart-link group

command to display the smart link group configuration on a device.
# Display the smart link group configuration on Device C.

[DeviceC] display smart-link group all

Smart link group 1 information:

Device ID: 000f-e23d-5af0

Preemption mode: ROLE

Preemption delay: 1(s)

Control VLAN: 10

Protected VLAN: Reference Instance 1

Member Role State Flush-count Last-flush-time

-----------------------------------------------------------------------------

GigabitEthernet1/0/1 MASTER DOWN 5 16:37:20 2010/02/21

GigabitEthernet1/0/2 SLAVE ACTVIE 3 17:45:20 2010/02/21

Smart link group 2 information:

Device ID: 000f-e23d-5af0

Preemption mode: ROLE

Preemption delay: 1(s)

Control VLAN: 110

Protected VLAN: Reference Instance 2

Member Role State Flush-count Last-flush-time

-----------------------------------------------------------------------------

GigabitEthernet1/0/2 MASTER ACTVIE 5 16:37:20 2010/02/21

GigabitEthernet1/0/1 SLAVE STANDBY 1 17:45:20 2010/02/21

The output shows that master port GigabitEthernet 1/0/1 of smart link group 1 fails, and slave port