H3C Technologies H3C S10500 Series Switches User Manual

Page 150

Advertising
background image

141

# Configure Switch A to work in preemptive mode so that it can become the master whenever it works

normally, and configure the preemption delay as five seconds to avoid frequent status switchover.

[SwitchA-Vlan-interface2] vrrp vrid 1 preempt-mode timer delay 5

2.

Configure Switch B

# Configure VLAN 2.

<SwitchB> system-view

[SwitchB] vlan 2

[SwitchB-Vlan2] port gigabitethernet 1/0/5

[SwitchB-vlan2] quit

[SwitchB] interface vlan-interface 2

[SwitchB-Vlan-interface2] ip address 202.38.160.2 255.255.255.0

# Create VRRP group 1 and set its virtual IP address to 202.38.160.111.

[SwitchB-Vlan-interface2] vrrp vrid 1 virtual-ip 202.38.160.111

# Set Switch B to work in preemptive mode. The preemption delay is five seconds.
[SwitchB-Vlan-interface2] vrrp vrid 1 preempt-mode timer delay 5

3.

Verify the configuration

After the configuration, Host B can be pinged successfully on Host A. To verify your configuration, use the
display vrrp verbose command.
# Display the detailed information of VRRP group 1 on Switch A.

[SwitchA-Vlan-interface2] display vrrp verbose

IPv4 Standby Information:

Run Mode : Standard

Run Method : Virtual MAC

Total number of virtual routers : 1

Interface Vlan-interface2

VRID : 1 Adver Timer : 1

Admin Status : Up State : Master

Config Pri : 110 Running Pri : 110

Preempt Mode : Yes Delay Time : 5

Auth Type : None

Virtual IP : 202.38.160.111

Virtual MAC : 0000-5e00-0101

Master IP : 202.38.160.1

# Display the detailed information of VRRP group 1 on Switch B.

[SwitchB-Vlan-interface2] display vrrp verbose

IPv4 Standby Information:

Run Mode : Standard

Run Method : Virtual MAC

Total number of virtual routers : 1

Interface Vlan-interface2

VRID : 1 Adver Timer : 1

Admin Status : Up State : Backup

Config Pri : 100 Running Pri : 100

Preempt Mode : Yes Delay Time : 5

Become Master : 4200ms left

Advertising