H3C Technologies H3C S10500 Series Switches User Manual

Page 204

Advertising
background image

195

Virtual IP : 10.1.1.10

Master IP : 10.1.1.2

VRRP Track Information:

Track Object : 1 State : Negative Pri Reduced : 30

# After shutting down the uplink interface on Switch A, display detailed information about VRRP group

1 on Switch B.

[SwitchB-Vlan-interface2] display vrrp verbose

IPv4 Standby Information:

Run Mode : Standard

Run Method : Virtual MAC

Total number of virtual routers : 1

Interface Vlan-interface2

VRID : 1 Adver Timer : 1

Admin Status : Up State : Master

Config Pri : 100 Running Pri : 100

Preempt Mode : Yes Delay Time : 0

Auth Type : None

Virtual IP : 10.1.1.10

Virtual MAC : 0000-5e00-0101

Master IP : 10.1.1.2

The output shows that when the uplink interface on Switch A is shut down, the priority of Switch A
decreases to 80. Switch A becomes the backup, and Switch B becomes the master. Packets from Host A

to Host B are forwarded through Switch B.

Advertising