9

Table 4 The fields in an OAMPDU

Field Description

Dest addr

Destination MAC address of the Ethernet OAMPDU
It is a slow protocol multicast address, 0180c2000002. Bridges cannot forward

slow protocol packets, so Ethernet OAMPDUs cannot be forwarded.

Source addr

Source MAC address of the Ethernet OAMPDU
It is the bridge MAC address of the sending side and is a unicast MAC address.

Type

Type of the encapsulated protocol in the Ethernet OAMPDU
The value is 0x8809.

Subtype

The specific protocol being encapsulated in the Ethernet OAMPDU
The value is 0x03.

Flags

Status information of an Ethernet OAM entity

Code

Type of the Ethernet OAMPDU

NOTE:

Throughout this document, a port with Ethernet OAM enabled is an Ethernet OAM entity or an OAM
entity.

Table 5 Functions of different types of OAMPDUs

OAMPDU type

Function

Information OAMPDU

Used for transmitting state information of an Ethernet OAM entity—including the
information about the local device and remote devices and customized
information—to the remote Ethernet OAM entity and maintaining OAM connections.

Event Notification
OAMPDU

Used by link monitoring to notify the remote OAM entity when it detects problems on
the link in between

Loopback Control
OAMPDU

Used for remote loopback control. By inserting the information used to
enable/disable loopback to a loopback control OAMPDU, you can enable/disable

loopback on a remote OAM entity.

How Ethernet OAM works

This section describes the working procedures of Ethernet OAM.

Ethernet OAM connection establishment

Ethernet OAM connection is the basis of all the other Ethernet OAM functions. OAM connection
establishment is also known as the “Discovery phase”, where an Ethernet OAM entity discovers remote

OAM entities and establishes sessions with them.
In this phase, interconnected OAM entities determine whether Ethernet OAM connections can be

established, by exchanging Information OAMPDUs to notify the peer of their OAM configuration

information and the OAM capabilities of the local nodes. An Ethernet OAM connection can be

established between entities that have matching Loopback, link detecting, and link event settings. After
an Ethernet OAM connection is established, Ethernet OAM takes effect on both sides.
For Ethernet OAM connection establishment, a device can operate in active Ethernet OAM mode or

passive Ethernet OAM mode, but a switch role will be somewhat different depending on the mode.