Fru functional descriptions, Base chassis, Fan module – Grass Valley K2 Media Client Service Manual Nov.18 2008 User Manual

Page 24: Raid drives, Base chassis fan module raid drives

Advertising
background image

24

K2 Media Client Service Manual

July 28, 2008

Chapter 1 Product Description

FRU functional descriptions

The Field Replaceable Units (FRUs) described in this section are as follows:

“Base chassis”

“Fan module”

“RAID drives”

“Power supplies”

“Removable media drives”

“Codec board”

“Mezzanine boards”

“RTP board”

“XLR board”

“RS-422 adapters”

“Dual Ethernet adapter”

“Graphics board”

“SCSI controller adapter”

“SCSI interface board”

“SCSI backplane”

“CPU motherboard”

For procedures, refer to

Chapter 5,

Removing and replacing FRUs.

Base chassis

For some serious system faults or for mechanical damage, the entire K2 Media Client
can be replaced as a base chassis FRU. Refer to

“Replacing a K2 Media Client” on

page 80

.

Fan module

The fan module has three fans and provides cooling for the K2 Media Client chassis.
Air intake is from the front of the K2 Media Client and outflow is through the rear.
The fan module is accessed behind the front bezel.

Refer to

“Fan module removal” on page 105

for procedures.

RAID drives

There are 12 slots for RAID drives in the K2 Media Client. They are located behind
the fan module in the front of the unit. Internal storage models have two RAID drives
for system data and five or ten RAID drives for media storage. External storage units
have only the two RAID drives for system data.

Advertising