Chapter 3 Service Procedures

17. Type

128

and press

Enter

.

18. Press

Escape

.

19. On the Logical Drive 01 menu, select

Accept

and press

Enter

.

The Easy Configuration - ARRAY SELECTION MENU screen is displayed.

20. For CHANNEL - 1, select the cell for ID 1.

21. Press the

SPACE

bar.

In the cell for CHANNEL - 1 ID 0, flashing text is displayed.

22. For CHANNEL -2, select the cell for ID 1.

23. Press the

SPACE

bar.

In the cell for CHANNEL - 2 ID 0, flashing text is displayed.

24. Press

Enter

.

The Select Configurable Array(s) menu area is displayed.

25. Press the

Space

bar.

The text SPAN-1 appears.

26. Press

F10

.

The Logical Drives 01 menu is displayed.

27. On the Logical Drive 01 menu, select

Accept

and press

Enter

.

28. Repeat step 20 to step 27 for ID 2 through ID 5.

29. On the Logical Drives Configured screen, verify that all six Logical Drives (LD)

are set to stripe size 128KB.

30. At the Save Configuration prompt, select

YES.

31. Press any key to continue.

32. Press

Escape

two times.

33. At the Exit? prompt, select

YES

.

34. Press

Ctrl + Alt + Delete

to reboot.

The K2 Media Client restarts, system drives are recognized, and startup processes
complete.

If you replaced the SCSI controller adapter, on restart check the SCSI controller
adapter BIOS startup screen. Make sure the firmware is the correct version. The
firmware version reports on the following line:

Standard FW 413Z DRAM = 128 MB (SDRAM)

Version 413Z is the correct version at the time of this writing. Check release notes to
verify the version.