NOTES FOR SAFE OPERATION

5

NOTES ON USE

WARNING

The SS5 motor is a synchronous motor equipped with a built-in, high performance magnet as a rotor.
The SS5 motor terminals continue to produce high voltage whenever the motor is rotating even if
inverter power is OFF. Observe the following when hadling the inverter.

S

Make sure the motor is stopped when carrying out maintenance, inspection or wiring.

S

Connect a low-voltage manual starter to the inverter output side when the motor is rotated

by the load even if the inverter power is OFF.

CAUTION

S

If using a motor with a PG, be sure to confirm the safety and adjust the PG zero-pulse be-

fore starting any operation.
Failure to observe this caution may cause the torque to be insufficient, which may result in the
following motor malfunctions:
• The motor is pulled in the direction of the load.
• The motor rotates in reverse.
• The motor does not rotate.
• The motor suddenly accelerates.

S

Before starting operation, be sure to set the motor constants according to the motor name-

plate values.
Failure to observe this caution may cause torque insufficiency, which result in motor malfunc-
tions:
• The motor is pulled in the direction of the load.
• The motor rotates in reverse direction.
• The motor does not rotate.
• The motor is suddenly accelerated.

RECEIVING

CAUTION

(Ref. page)

S

Do not install or operate any inverter which is damaged or has missing

parts.
Failure to observe this caution may result in personal injury or equipment damage.

14