1 periodic inspection, 2 parts replacement schedule (guidelines) – Yaskawa Varispeed-686SS5 CIMR-SSA User Manual

Page 65

Advertising
background image

66

6.1

PERIODIC INSPECTION

The VS-686SS5 will function longer if it is kept clean, cool and dry, while observing the precautions
listed in Par. 2.3. Check for tightness of electrical connections, discoloration or other signs of
overheating or aging. Use Table 29 as your inspection guide. Before servicing, turn OFF AC main
circuit power and be sure that the CHARGE LED is OFF.

Table 29

Periodic Inspection

Component

Check

Corrective Action

External Terminals,

Unit Mounting Bolts

Loose screws

Tighten.

Unit Mounting Bolts,

Connectors, etc.

Loose connectors

Tighten.

Heatsink

Build-up of dust and dirt

Blow with dry compressed air of 39.2¢10

4

to

58.8¢10

4

Pa (4 to 6kg¡cm

2

) pressure.

Printed Circuit Board

Accumulation of conductive dust or oil.

Blow with dry compressed air of 39.2¢10

4

to

58.8¢10

4

Pa (4 to 6kg¡cm

2

) pressure. If dust and

oil cannot be removed, replace the board.

Cooling Fan

For abnormal noise and vibration.

Whether the cumulative operation time

exceeds 20,000 hours or not.

Replace the cooling fan.

Power Elements

Accumulation of dust and dirt

Blow with dry compressed air of 39.2¢10

4

to

58.8¢10

4

Pa (4 to 6kg¡cm

2

) pressure.

Smoothing Capacitor

Discoloration or odor

Replace the capacitor or inverter unit.

6.2

PARTS REPLACEMENT SCHEDULE (GUIDELINES)

Replace the following parts periodically, for a long, safe, trouble free working life of VS-686SS5.

Table 30

Parts Replacement Schedule

Parts

Interval (Approx.)

Remarks

Cooling Fan

2 to 3 years

Replace with new one.

Smoothing Capacitor

5 years

Replace with new one. (Decided after

inspection.)

Breakers or Relays

Decided after inspection

Breakers or Relays

Decided after inspection.

Fuse

10 years

Replace with new one.

Aluminum Electrolytic

Capacitor on PC Board

5 years

Replace with new one. (Decided after

inspection.)

Operating conditions are as follows:

Ambient temperature : 30_C yearly average
Load factor

: 80% or below

Operation rate

: 20 hours or below /day

NOTE