Yaskawa Varispeed-686SS5 CIMR-SSA User Manual

Page 87

Advertising
background image

88

Table A−5 Constants List (Cont’d)

Constant

No.

Name

Initial

Setting

User

Setting

Constant

No.

Name

Initial

Setting

User

Setting

L1-01

Motor protection selection

1

o1-01

Monitor selection

6

L1-02

Motor protection time

60.0

o1-02

Monitor selection after power up

1

L2-01

Momentary power loss detection

0

o1-03

Units of speed reference setting and
monitor

1

L2-02

Momentary power loss ridethru time

*1

o2-01

LOCAL/REMOTEkeyenable/disable

1

L2-03

Deceleration time at momentary pow-
er loss

30.0

o2-02

STOP key during control circuit termi-
nal operation

0

L2-05

Undervoltage detection level

190

*2

o2-04

kVA selection

*1 *5

L3-01

Overvoltage prevention function
selection

*3

1

o2-05

Speed reference setting method selec-
tion

0

L4-01

Speed detection level

0.0

o2-06

Operation selection when digital opera-
tor is disconnected

0

L4-02

Speed detection width

2.0

o2-07

Cumulative operation time setting

L4-03

Speed detection level (+/-)

0.0

o2-08

Cumulative operation time selection

0

L4-04

Speed detection width (+/-)

2.0

T1-02

Tuning mode

0

L4-05

Operation when speed reference is
missing

0

T1-03

Tuning item selection

1

L5-01

Number of auto restart attempts

0

L5-02

Auto restart operation selection

0

L6-01

Torque detection selection 1

0

L6-02

Torque detection level 1

150

L6-03

Torque detection time 1

0.1

L6-04

Torque detection selection 2

0

L6-05

Torque detection level 2

150

L6-06

Torque detection time 2

0.1

L7-01

Forward torque limit

160

L7-02

Reverse torque limit

160

L7-03

Forward regenerative torque limit

160

L7-04

Reverse regenerative torque limit

160

L8-01

Protect selection for internal DB resis-
tor

*4

0

L8-02

Inverter overheat pre-alarm level

95

L8-03

Operation selectionafter inverterover-
heat pre-alarm

3

L8-05

Input open-phase protection selection

0

L8-07

Output open-phase protection selec-
tion

0

L8-10

Ground fault protection selection

1

L9-01

Step-out protection selection

1

L9-02

Output current unbalance protection
selection

*6

1

*1

Setting range and initial setting differ depending on inverter capacity.

*2

Set value for 200V class. For 400V class, the value is twice as that of 200V class.

*3

When using a braking resistor unit, set L3-01 to “0.”

*4

When using a mounting-type braking resistor unit (model ERF), set L8-01 to “1.”

*5

Not initialized.

*6

The display is applicable for software No. 1033 or later (FLASH side). To check which
version is being used, refer to U1-14.