Table 18 typical operation by digital operator – Yaskawa Varispeed-686SS5 CIMR-SSA User Manual

Page 53

Advertising
background image

54

Table 18

Typical Operation by Digital Operator

Step

Description

Key Sequence

Digital Operator Display

1

Power ON

• Displays speed reference value.

G

Operation condition setting

• Seslect LOCAL mode.

LOCAL

REMOTE

REMOTE LED (SEQ, REF) ON

2

Forward jog run (10%)

• Perform jog run. (Runs while depressing

JOG key. Motor rotates at low speed.)

JOG

G

3

Speed Setting

• Displays speed reference value.

G

• Change the value.

RESET

Change the value
by depressing

G

• Write-in the value.

DATA

ENTER

(Displays for 2 seconds.)

G

• Select motor speed monitor display.

DSPL

G

4

Forward run

• Perform forward run. (25%)

RUN

Motor rotates by de-
pressing RUN key.

RUN

RUN LED ON

FWD LED ON

G

5

Speed reference value change (25% → 100%)

• Select speed reference value display.

DSPL

Depress 4 times.

G

• Change the value.

RESET

Change the value
by depressing

Digit to be changed blinks.

G

• Write-in the value.

(Motor min

-1

increases.)

DATA

ENTER

(Displays for 2 seconds.)

G

• Select motor speed monitor display.

DSPL

G

6

Reverse run

• Switch to reverse run.

Motor decelerates to stop. Then reverse
run startrs at set min

-1

of 100%.

FWD
REV

REV LED ON

G

7

Stop

• Decelerates to stop.

STOP

STOP LED ON

(RUN LED blinks during deceleration.)

G

Advertising