Adjust zero-pulse when replacing PG or motor (i.e. when relative position of connection be-
tween motor and PG).

The operation pattern below shows PG zero-pulse adjustment method. If an error is dis-
played during adjustment, refer to APPENDIX 5.

Forward Run

at Low Speed

(30 min

-1

)

Power ON

Adjustment Start

Pre-adjustment

Processing after

Adjustment

Adjustment Complete

Automatic Operation

1

2

3

4

5

Forward Run

at Low Speed

(30 min

-1

)

Fig.

22

Operation Pattern of PG Zero-pulse Adjustment

Table 16

PG Zero-pulse Adjustment

Step

Description

Key Sequence

Digital Operator Display

1

Power ON

• Displays speed reference value.

G

REMOTE LEDs (SEQ, REF) ON.

A1-02=06 (Control method: flux vector)

2

Pre-adjustment

• Move to program mode.

DRIVE

PRGM

Constant No. display

• Move to tuning item selection (T1-03).

RESET

• Verify the set value. (Go to : for “01.”)

DATA

ENTER

• Change the value to “01” (adjusting of PG

zero-pulse only).

RESET

• Write-in the value.

DATA

ENTER

Displays for 0.5 seconds.