Yaskawa MP2300S Basic Module User Manual

Page 183

Advertising
background image

5.4 Self-configuration

5.4.2 Definition Information Updated with Self-Configuration

5-50

5.4.2 Definition Information Updated with Self-Configuration

Now, the definition information updated during executing the self-configuration and the module configuration defini-
tion example based on the module combination are as follows:

( 1 ) Definition Data of MP2300S Basic Module

[ a ] I/O Allocations

[ b ] 218IFA Definition

Note: The self-configuration allows you to connect with MPE720 for engineering transmission. In order to carry

out MEMOBUS message transmission, manually use an automatic reception and I/O message commu-
nication separately, or MSG-SND/MSG-RCV functions are required.

Item

Allocation

218IFA

• Start I/O register: IW0000/OW0000
• End I/O register: IW07FF/OW07FF

(Input register: IW0000 to IW07FF,
Output register: OW0000 to OW07FF)

SVB

MECHATROLINK

• Start I/O register: IW0800/OW0800
• End I/O register: IW0BFF/OW0BFF

(Input register: IW0800 to IW0BFF,
Output register: OW0800 to OW0BFF)

Motion Parameter

• Start motion register: IW8000/OW8000
• End motion register: IW87FF/OW87FF

(Input register: IW8000 to IW87FF,
Output register: OW8000 to OW87FF)

SVR

Motion Parameter

• Start motion register: IW8800/OW8800
• End motion register: IW8FFF/OW8FFF

(Input register: IW8800 to IW8FFF,
Output register: OW8800 to OW8FFF)

M-EXECUTOR

• Start I/O register: IW0C00/OW0C00
• End I/O register: IW0C3F/OW0C3F

(Input register: IW0C00 to IW0C3F,
Output register: OW0C00 to OW0C3F)

Item

Allocation

Local IP Address

192.168.1.1

Subnet Mask

255.255.255.0

Gateway IP Address

0.0.0.0

Module Name Definition

“CONTROLLER NAME”

System Port
(engineering port)

9999 (UDP)

Check & Monitor Time of MEMOBUS
response

0 s

Retransmit Count

0