The following table provides the valid setting items for each communication protocol type.
Note:
√ : Enable
– : Disable
Setting Item
Communication Protocol Type
Extended
MEMOBUS
MEMOBUS
MELSEC
Non-proce-
dure
MODBUS/
TCP
Readout of Input Relay
√
√
–
–
√
Readout of Input Register
√
√
–
–
√
Readout/Write-in of Coil
√
√
–
–
√
Readout/Write-in of Hold Register
√
√
√
–
√
Write-in Width of Coil/Hold Register (LO)
√
√
√
–
√
Write-in Width of Coil/Hold Register (HI)
√
√
√
–
√