6.4 Communication with PLC Manufactured by Mitsubishi Electric Corporation (MELSEC protocol)

6.4.1 When the MP2300S Acts as Slave (automatic receive function is used)

6-78

3.

Click the Easy Setting Button in the Message Communication area of the connection parameter set-
ting.

4.

Set up the communication settings in the Message Communication Easy Setting Window.

„

How to set up in the Message Communication Easy Setting Window

c When automatic receive is used, select “1” for the Connect No.
d Set Port No. of MP2300S side (“10001,” for example).
e Select MELSEC for Communication Protocol Type, and click the Default Button.
f Select Connect Type (TCP, for example).
g Select Code (BIN, for example).
h Set Node port IP Address for the other device (MELSEC Q series) to be connected (“192.168.001.002,” for

example).

i Set Port No. of the other device (MELSEC Q series) to be connected (“10001,” for example).
j Click OK.

c

d

e

f

h

g

i

j