Yaskawa MP2300S Basic Module User Manual

Page 63

Advertising
background image

2.2 Basic Module

2.2.5 Built-in SVB Module

2-37

Specifications and Functions

[ b ] MECHATROLINK Communication Specifications

* Up to 16 stations can be connected if a JEPMC-REP2000 MECHATROLINK-II Repeater is not used. Refer to

Chapter 8 MECHATROLINK-II Repeater of the Machine Controller MP900/MP2000 Series User’s Manual
MECHATROLINK System
(manual number: SIEZ-887-5.1) for details.

[ c ] Maximum Number of Slave Stations

The maximum numbers of slave stations that can be connected to the SVB-01 Module are listed below.

„

MECHATROLINK Communication Setting and Maximum No. of Slave Stations

Œ

Refer to 3.4.2 MECHATROLINK Transmission Definition of Machine Controller MP2000 Series Built-in SVB/SVB-01
Motion Module User’s Manual
(manual number: SIEP C880700 33) for information on the settings for MECHA-
TROLINK transmission.

Item

MECHATROLINK-I

MECHATROLINK-II

Topology

Bus

Bus

Transmission Media

Twisted-pair cable

Twisted-pair cable

Transmission Distance

50 m max.
(can be extended to 100 m by connecting
repeaters)

50 m max.
(can be extended to 100 m by connecting
repeaters)

Minimum Distance
between Stations

0.3 m

0.5 m

Baud Rate

4 Mbps

10 Mbps

Communication Cycle

2 ms

0.5 ms, 1 ms, 1.5 ms, or 2 ms

Number of Connectable
Stations

Up to 14 stations

Up to 21 stations

*

(SERVOPACK for up to 16

axes)

Communication Control
Method

Cyclic

Cyclic

Media Access Control
Method

1:N

2:N

Communication Mode

Control communication

Control communication

Error Control

CRC check

CRC check

MECHATROLINK Communication Setting

Maximum Number of

Slave Stations

Communication Method

Baud Rate

Communication

Cycle

MECHATROLINK-I

4 Mbps

2 ms

14

MECHATROLINK-II
(17-byte Mode)

10 Mbps

0.5 ms

6

1 ms

15

MECHATROLINK-II
(32-byte Mode)

10 Mbps

0.5 ms

4

1 ms

9

1.5 ms

15

2 ms

21 (SERVOPACK for up to

16 axes)

Advertising