Appendix G MSG-SND/MSG-RCV Functions (Ethernet)

G.1 Message Transmit Function (MSG-SND)

A-54

7.

Param (parameter list start address)

Specify the start address of the parameter list. For the “parameter list,” 17 words are automatically assigned from
the configured address. In the parameter list, enter the function code and its relevant parameter data. Also, pro-
cess result and status are output.

Note: For more information about the parameter list, refer to the parameter details for each protocol from

G.1.4 Function Setting and Parameter Details for MEMOBUS and Extended MEMOBUS Protocols
to G.1.7 Function Setting and Parameter Details for Non-procedural Protocol.

Example: When “DA00000” is specified as a parameter list start address.

( 2 ) Output Item

The following table shows the registers available for each output item.

1.

Busy (in process)

Specify a bit that reports a message is transmitting.
The Busy bit is ON while executing a message transmission or forced abort process.
Keep Execute or Abort ON while Busy is ON.

2.

Complete (process completed)

Specify a bit that reports that message transmission has ended.
When a message transmission or forced abort process is completed properly, the Complete bit will turn ON only
for one scan.

Parameter list

F

… … … 0

Register

PARAM00

PARAM01

PARAM02

PARAM03

PARAM04

PARAM05

PARAM06

PARAM07

PARAM08

PARAM09

PARAM10

PARAM11

PARAM12

PARAM13

PARAM14

PARAM15

PARAM16

DW00000

DW00001

DW00002

DW00003

DW00004

DW00005

DW00006

DW00007

DW00008

DW00009

DW00010

DW00011

DW00012

DW00013

DW00014

DW00015

DW00016

Input Item

I/O Option

Available Register

Busy
Complete
Error

B-VAL

Every bit type register
(except #, C registers),
Same as above with subscript