Appendix g msg-snd/msg-rcv functions (ethernet), G.1 message transmit function (msg-snd), A-51 – Yaskawa MP2300S Basic Module User Manual

Page 373

Advertising
background image

Appendix G MSG-SND/MSG-RCV Functions (Ethernet)

G.1 Message Transmit Function (MSG-SND)

A-51

Appendices

Appendix G MSG-SND/MSG-RCV Functions (Ethernet)

G.1

Message Transmit Function (MSG-SND)

This section explains the message transmit function (MSG-SND) used in a ladder program when transmitting mes-
sages.

G.1.1 Specification Overview of the Message Transmit Function

* 1. The meanings of I/O options are as follows:

Œ

B-VAL: Specify I/O by bit type data.

Œ

I-REG: Specify I/O by integer type data. When specifying, set an integer type register number.
As for the input only, it can be a constant (literal).

Œ

Address input: The address of the specified register (any integer register) is passed to the function.

* 2. When transmitting in MEMOBUS, Extended MEMOBUS, MELSEC, OMRON, or MODBUS/TCP protocol, set the

communication protocol (Pro-Typ) to MEMOBUS(=1). The communication device automatically converts the proto-
col.

* 3. Non-procedure 1: In non-procedural communication, data is transmitted on a per-word basis.

Non-procedure 2: In non-procedural communication, data is transmitted on a per-byte basis.

Function Name

MSG-SND

Function

Transmits messages to a remote station on the circuit specified by the communication device type.
Supports multiple protocols.
Keep the execution command (Execute) until Complete or Error turns ON.

Function Defi-
nition

I/O Definition

No.

Name

I/O Option

*1

Contents

Input Item

1

Execute

B-VAL

Executes a transmission

2

Abort

B-VAL

Forcibly ends a transmission

3

Dev-Typ

I-REG

Communication device type
Ethernet (218IF) = 6, Ethernet (218IFA, 218IFB, 218IFC) = 16

4

Pro-Typ

I-REG

Communication protocol
MEMOBUS

*2

= 1, non-procedure 1

*3

= 2,

non-procedure 2

*3

= 3

5

Cir-No

I-REG

Circuit number
Ethernet (218IF) = 1 to 8, Ethernet (218IFA) = 1 to 8

6

Ch-No

I-REG

Communication buffer channel number
Ethernet (218IF) = 1 to 10, Ethernet (218IFA) = 1 to 4

7

Param

Address input

Parameter list start address
(MA, DA)

Output Item

1

Busy

B-VAL

In process

2

Complete

B-VAL

Process completed

3

Error

B-VAL

Error has occurred

Execute

Abort

Dev-Typ

Pro-Typ

Cir-No

Ch-No

Param

MSG

SND

Busy

Complete

Error