3 function lists, 1 ) plc function specifications – Yaskawa MP2300S Basic Module User Manual

Page 30

Advertising
background image

2.1 Specifications

2.1.3 Function Lists

2-4

2.1.3 Function Lists

( 1 ) PLC Function Specifications

The following table shows the PLC function specifications.

* For details on optional functions, refer to Appendix H Optional Functions.

Item

Specifications

Control Method

Sequence: High-speed and low-speed scan methods

Programming
Language

Ladder diagram: Relay circuit
Text-type language: Numeric operations, logic operations, etc.

Scan

Two scan levels: High-speed scan and low-speed scan

High-speed scan time setting:

0.5 to 32 ms (Integral multiple of MECHATROLINK communi-

cation cycle)

Low-speed scan time setting:

2 to 300 ms (Integral multiple of MECHATROLINK communi-

cation cycle)

User Drawings,
Functions and Motion
Programs

Startup drawings (DWG.A):

Interrupt processing drawings
(DWG.I):
High-speed scan process drawings
(DWG.H):
Low-speed scan process drawings
(DWG.L):
Number of steps:
User functions:
Motion programs and sequence programs:

64 drawings max. Up to three hierarchical drawing
levels
64 drawings max. Up to three hierarchical drawing
levels
200 drawings max. Up to three hierarchical drawing
levels
500 drawings max. Up to three hierarchical drawing
levels
Up to 1,000 steps per drawing
Up to 500 functions
A total of up to 256

Revision history of drawings and motion programs
Security function for drawings and motion programs

Data Memory

Common data (M) registers:
System (S) registers:
Drawing local (D) registers:
Drawing constant (#) registers:
Input (I) registers:
Output (O) registers:
Constant (C) registers:

64 kwords
8 kwords
Up to 16 kwords per drawing
Up to 16 kwords per drawing
32 kwords (including internal input registers)
32 kwords (including internal output registers)
16 kwords

Trace Memory

Data trace:

128 kwords (32 kwords

× 4 groups), 16 points defined

Memory Backup

Program memory:

Flash memory: 8 MB (User area: 5.5 MB) definition files,
ladder programs, motion programs, etc.
Data other than battery backup data

Data memory: Battery backup: 512 KB, M registers, S registers, alarm history, trace data

Data Types

Bit (relay):

0: OFF/1: ON

Integer:

−32768 to +32767

Double-length integer:

−2147483648 to +2147483647

Real number:

± (1.175E-38 to 3.402E+38)

Register Designation
Method

Register number:

Direct designation of register number

Symbolic designation:

Up to 8 alphanumeric characters (up to 200 symbols per drawing)
With automatic number or symbol assignment

Instructions

Program control instructions:

14 instructions

Direct I/O instructions:

2 instructions

Relay circuit instructions:

14 instructions (including set and reset coils)

Logic operation instructions:

3 instructions

Numeric operation instructions:

16 instructions

Numeric conversion instructions:

9 instructions

Numeric comparison instructions:

7 instructions

Data manipulation instructions:

14 instructions

Basic function instructions:

10 instructions

Table data manipulation instructions:

11 instructions

DDC instructions:

13 instructions

System functions:

9 instructions

Optional Functions*

Clearing D registers at startup
Security

Advertising