2.2 Basic Module

2.2.7 M-EXECUTOR Module (Motion Program Executor)

2-53

Specifications and Functions

( 3 ) Module Configuration Definition

(a) Details of Module Configuration Definition Window

Click MP2300S in the Controller area to display the details of the basic module functions in the Module Details area.
The cell No.5 provides a detailed definition of M-EXECUTOR.

Items displayed in the Module Details area show the following:

: Available, – : Not available

Item

Description

Change

Slot Number

Sub-slot number. Double-click to open the M-EXECUTOR detailed definition
screen.

Module Type

A module name appears. Changing the name to UNDEFINED enables you to
disable M-EXECUTOR functions.

Controller Number

Not used. Fixed to “–”.

Circuit Number

Not used. Fixed to “–”.

I/O Start Register

Start register of the M-EXECUTOR I/O register (valid range: 0000-7FFFh, size:
40h words)

I/O End Register

End register of the M-EXECUTOR I/O register (valid range: 0000-7FFFh, size:
40h words)

Disable Input

Not used. Fixed at “blank”.

Disable Output

Not used. Fixed at “blank”.

Motion Start Register

Not used. Fixed at “– – – –”.

Motion End Register

Not used. Fixed at “– – – –”.

Details

Not used.

Status

M-EXECUTOR Module status in online mode.