Counts reset 0, Cpu error 1, Cpu error 2 – Extron electronic 3000B User Manual

Page 106: Cpu error 3, Cpu error 4, Cpu error 5, Exatron 3000b

Advertising
background image

Exatron 3000B

www.exatron.com

6-5

Chapter 6 Display Dictionary

3. Verify that the plunger is mechanically adjusted correctly. Perform the Self Adjust Z procedure

described in Chapter 5, Diagnostics.

4. Pressing

the

[Enter] button will skip past this error, but BE CAREFUL IN SELECTING THIS

OPTION, because pressing the [Enter] button will cycle the plunger down which may destroy
the device it is holding.

5. Pressing

the

[Clear] button will flush all devices from the handler.

6. Use Diagnostics “Solenoid Check” to verify that the vacuum is working properly.

COUNTS RESET 0

This indicates that all output tube counts and all total counts have been reset to 0000.
For your reference only.

CPU ERROR 1
CPU ERROR 2
CPU ERROR 3
CPU ERROR 4
CPU ERROR 5

All of the above errors are critical. The handler's control program has detected a large problem, and has
stopped operation. Use the following procedure to resolve this problem:

1. Write down exactly which CPU ERROR message is displayed.

2. Write down exactly which output cover LEDs are on and whether they are flashing.

3. Write down to the best of your knowledge what message(s) was displayed by the handler just

before the error.

4. Write down to the best of your knowledge what the handler was doing just before the error.

5. Power down the handler.

6. Power the handler back up and answer all of the MOD SET UP ? YS questions.

7. Resume handler operation.

8. Fax your notes to E

XATRON

as soon as possible. We will answer your fax with an

explanation of what occurred and a free software update to permanently correct the problem.

Advertising